CVE Intelligence
Skip to main content
CRITICAL

CVE-2019-5644

CVE-2019-5644 — C4G BLIS Improper Access Control

Computing For Good's Basic Laboratory Information System (also known as C4G BLIS) version 3.5 and earlier suffers from an instance of CWE-284, "Improper Access Control." As a result, an unauthenticated user may alter several facets of a user account, including promoting any user to an administrator.

Published Updated Sources: cvelistV5, rapid7

Triage

Is it exploited, how likely is exploitation, what does it touch, and how severe do the scoring sources call it.

Exploitation

Unreported

no source claims exploitation

EPSS

1%

chance of exploitation in 30 days

Affects

computing for good

basic_laboratory_information_system

CVSS base

10

CRITICAL

Affected scope

The catalog records vendors and products as separate lists, not pairs, so which product belongs to which vendor is not something this page can say.

Products (1)

basic laboratory information system

Every base score collected

Sources score independently and disagree; each row says who scored it and under which version.

ScoreVersionSeverityExpl.ImpactSource
10CVSS 3.1CRITICALcvelistV5

Weakness & attack patterns

  • CWE-284

Attack patterns reported against this CVE. The ATT&CK techniques below are inferred from its weakness class.

  • T1027.009Obfuscated Files or Information: Embedded Payloads
  • T1546.004Event Triggered Execution: .bash_profile and .bashrc
  • T1546.016Event Triggered Execution: Installer Packages

References

1 on the record

Elsewhere on this site

Not in any source we poll

Listed rather than left blank: an empty field and an unmeasured one look identical on screen, and only one is a reason to look elsewhere.

  • No confirmed IOCs, IP addresses, domains, file hashes, or malware artifacts supplied.
  • No organization-specific asset inventory, compensating-control status, or patch deployment evidence supplied.
  • No exploit packet captures, log samples, or incident case IDs supplied.