CVE Intelligence
Skip to main content
CRITICAL

CVE-2020-10276

CVE-2020-10276 — RVD#2558: Default credentials on SICK PLC allows disabling safety features

The password for the safety PLC is the default and thus easy to find (in manuals, etc.). This allows a manipulated program to be uploaded to the safety PLC, effectively disabling the emergency stop in case an object is too close to the robot. Navigation and any other components dependent on the laser scanner are not affected (thus it is hard to detect before something happens) though the laser scanner configuration can also be affected altering further the safety of the device.

Published Updated Sources: cvelistV5, Alias

Triage

Is it exploited, how likely is exploitation, what does it touch, and how severe do the scoring sources call it.

Exploitation

Unreported

no source claims exploitation

EPSS

1%

chance of exploitation in 30 days

CVSS base

9.8

CRITICAL

Affected scope

The catalog records vendors and products as separate lists, not pairs, so which product belongs to which vendor is not something this page can say.

Products (1)

mir100

Every base score collected

Sources score independently and disagree; each row says who scored it and under which version.

ScoreVersionSeverityExpl.ImpactSource
9.8CVSS 3.0CRITICALcvelistV5

Weakness & attack patterns

  • CWE-798

Attack patterns reported against this CVE. The ATT&CK techniques below are inferred from its weakness class.

  • T1552.001Unsecured Credentials: Credentials in files
  • T1078.001Valid Accounts: Default Accounts

References

1 on the record

Elsewhere on this site

Not in any source we poll

Listed rather than left blank: an empty field and an unmeasured one look identical on screen, and only one is a reason to look elsewhere.

  • No confirmed IOCs, IP addresses, domains, file hashes, or malware artifacts supplied.
  • No organization-specific asset inventory, compensating-control status, or patch deployment evidence supplied.
  • No exploit packet captures, log samples, or incident case IDs supplied.