CVE-2023-50219
CVE-2023-50219 — Inductive Automation Ignition RunQuery Deserialization of Untrusted Data Remote Code Execution Vulnerability
Inductive Automation Ignition RunQuery Deserialization of Untrusted Data Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Inductive Automation Ignition. Authentication is required to exploit this vulnerability. The specific flaw exists within the RunQuery class. The issue results from the lack of proper validation of user-supplied data, which can result in deserialization of untrusted data. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-21625.
Published Updated Sources: cvelistV5, zdi
Triage
Is it exploited, how likely is exploitation, what does it touch, and how severe do the scoring sources call it.
Exploitation
Unreported
no source claims exploitation
EPSS
2%
chance of exploitation in 30 days
CVSS base
8.8
HIGH
CISA SSVC assessment
Three decision points CISA publishes for the CVEs it assesses · SSVC 2.0.3. A stakeholder decision, not a severity score.
Exploitation
None
none · proof-of-concept · active
Automatable
No
can an attacker script all four kill-chain steps
Technical impact
Total
partial · total control of the vulnerable component
Affected scope
The catalog records vendors and products as separate lists, not pairs, so which product belongs to which vendor is not something this page can say.
Vendors (2)
Products (1)
Every base score collected
Sources score independently and disagree; each row says who scored it and under which version.
| Score | Version | Severity | Expl. | Impact | Source |
|---|---|---|---|---|---|
| 8.8 | CVSS 3.0 | HIGH | — | — | cvelistV5 |
Weakness & attack patterns
- CWE-502
References
2 on the record
- www.zerodayinitiative.com/advisories/ZDI-24-014/
x_research-advisory
- security.inductiveautomation.com/?tcuUid=fc4c4515-046d-4365-b688-693337449c5b
vendor-advisory
Elsewhere on this site
- inductive automationevery CVE for this vendor
- inductiveautomationevery CVE for this vendor
- CWE-502other pages naming this weakness
Not in any source we poll
Listed rather than left blank: an empty field and an unmeasured one look identical on screen, and only one is a reason to look elsewhere.
- No confirmed IOCs, IP addresses, domains, file hashes, or malware artifacts supplied.
- No organization-specific asset inventory, compensating-control status, or patch deployment evidence supplied.
- No exploit packet captures, log samples, or incident case IDs supplied.