CVE Intelligence
Skip to main content
criticalAuth Bypasspublic exploit

CVE-2026-3869

CVE-2026-3869 — CWE-303 : Incorrect Implementation of Authentication Algorithm vulnerability exists that could cause loss of confidentiality, integrity and…

CWE-303 : Incorrect Implementation of Authentication Algorithm vulnerability exists that could cause loss of confidentiality, integrity and availability of the PLC provided an application project with a lower application level is running on the PLC.

Published Updated Sources: NVD, Schneider Electric (CNA), GitHub, SOCRadar CTI

Triage

Is it exploited, how likely is exploitation, what does it touch, and how severe do the scoring sources call it.

Exploitation

Reported

not confirmed by CISA

EPSS

0%

ahead of 0% of scored CVEs

Affects

Schneider Electric

2 products listed

CVSS base

9.2

critical

Remediation

The vendor's own words where we have them.

Upgrade Modicon M580 to a fixed release. Apply vendor patches per advisory and restrict external exposure of the affected component until patched.

First 24 hours

Ordered from the record's own fields — exposure first, because you cannot patch what you have not found.

  • Identify exposed assets running affected vendor/product/version combinations.
  • Prioritize based on EPSS, PoC availability, and external exposure.
  • Search available logs for exploit probes, errors, authentication anomalies, or suspicious child processes matching the vulnerability class.

Affected scope

Vendor, product and version as the advisories word them.

VendorProductVersionsStatus
Schneider ElectricModicon M580All versions with an application level below 4.00Vulnerable
Schneider ElectricModicon M580 SafetyAll versions with an application level below 4.20Vulnerable

Attack characteristics

The CVSS vector, decoded. It describes the attack, not your exposure to it.

Attack Complexity

Low

Attack Vector

Network

Privileges Req

None

User Interaction

None

Every base score collected

Sources score independently and disagree; each row says who scored it and under which version.

ScoreVersionSeverityExpl.ImpactSource
9.2CVSS 4.0criticalSchneider Electric (CNA)

CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

What this weakness leads to

MITRE's own consequences and mitigations for the weakness class — the authority's wording, not guidance derived from the CVSS vector.

MITRE

CWE-303 · Incorrect Implementation of Authentication Algorithm

  • Bypass Protection Mechanism::

Weakness & attack patterns

  • CWE-303

Attack patterns reported against this CVE. The ATT&CK techniques below are inferred from its weakness class.

CAPEC-90 · Reflection Attack in Authentication Protocol

Public exploit

Capability, not use: code existing is a different claim from anyone running it.

Repositories

11

Social mentions

Posts naming this CVE. Attention, not evidence of exploitation — it spikes on disclosure and decays whether or not anything is exploited.

Detection

Read off the CVSS vector and the weakness class. Starting points, not rules we have tested.

  • Prioritize edge telemetry for network-reachable Modicon M580, Modicon M580 Safety.
  • Monitor for scanner or exploit-pattern traffic after 11 public PoC repositories were reported.
web/proxy/WAF logsapplication logsnetwork IDS/IPSidentity provider logsauthentication audit logs

Timeline

What happened to this CVE, newest first — with the readings a source repeats on a schedule counted underneath rather than listed.

  1. 2026
  2. Added · CVSS 3.1 9.2 (AV:N)

    Sep 11, 2026 · NVD

  3. Initial · CVE published

    Sep 11, 2026 · NVD

  4. CVE published by MITRE.

    Sep 11, 2026 · SOCRadar CTI

Source activity

Readings a source repeats on a schedule, counted rather than listed.

  • Tweets · 2 times tweeted.Sep 10, 2026 · SOCRadar CTI

References

1 on the record

Elsewhere on this site

Not in any source we poll

Listed rather than left blank: an empty field and an unmeasured one look identical on screen, and only one is a reason to look elsewhere.

  • No confirmed IOCs, IP addresses, domains, file hashes, or malware artifacts supplied.
  • No organization-specific asset inventory, compensating-control status, or patch deployment evidence supplied.
  • No exploit packet captures, log samples, or incident case IDs supplied.
Answered from this record1

What should defenders know first?

CVE-2026-3869 is CWE-303 : Incorrect Implementation of Authentication Algorithm vulnerability exists that could cause loss of confidentiality, integrity and…, a critical vulnerability affecting Modicon M580, Modicon M580 Safety from Schneider Electric. The current evidence does not list it in CISA KEV, and the exploit status is: Exploitation is reported, but no independent confirmation is available in the sources we have. Public exploit evidence is: 11 public PoC repositories reported; 0 marked weaponized in current dataset. The affected-version evidence is listed in the key facts and affected products tables. Defenders should first verify whether exposed or business-critical assets run those versions, then apply vendor patches or mitigations, restrict reachable attack surface, and preserve logs for detection review. CVSS 9.2 describes technical severity, while EPSS 0% helps estimate near-term exploit likelihood; neither replaces asset context. Unknown fields should remain explicit in tickets, and threat actor, IOC, victimology, or payload claims should not be added unless a cited source supports them. Monitor CISA KEV, vendor advisories, NVD changes, public PoC repositories, and internal telemetry for update triggers.