CVE Intelligence
Skip to main content
HIGH

CVE-2026-4638

CVE-2026-4638 — Plaintext Password Disclosure via VBScript Sensor Error Message in Paessler PRTG Network Monitor

PRTG Network Monitor before version 26.2.120.1449 ships a demo EXE/Script sensor that multiplies two integer parameters using cscript.exe. If a non-numeric value is passed instead, cscript.exe raises a 'Type mismatch' runtime error that includes the offending parameter value in plaintext. PRTG provides a documented placeholder variable, %windowspassword, which resolves to the configured Windows/domain password used by PRTG and can be passed as a sensor parameter. Any PRTG user who is not restricted to read-only access and is permitted to create sensors (the default for non-read-only users) can pass %windowspassword as an argument to the demo VBScript sensor, triggering the type-mismatch error and causing PRTG to display the plaintext password in the sensor's error output.

Published Updated Sources: cvelistV5, SEC-VLab

Triage

Is it exploited, how likely is exploitation, what does it touch, and how severe do the scoring sources call it.

Exploitation

Unreported

no source claims exploitation

EPSS

0%

chance of exploitation in 30 days

Affects

paessler

prtg_network_monitor

CVSS base

7.1

HIGH

CISA SSVC assessment

Three decision points CISA publishes for the CVEs it assesses · SSVC 2.0.3. A stakeholder decision, not a severity score.

CISA

Exploitation

None

none · proof-of-concept · active

Automatable

No

can an attacker script all four kill-chain steps

Technical impact

Partial

partial · total control of the vulnerable component

Affected scope

The catalog records vendors and products as separate lists, not pairs, so which product belongs to which vendor is not something this page can say.

Vendors (1)

Products (1)

prtg network monitor

Every base score collected

Sources score independently and disagree; each row says who scored it and under which version.

ScoreVersionSeverityExpl.ImpactSource
7.1CVSS 4.0HIGH——cvelistV5

Weakness & attack patterns

  • CWE-209

Detection

Read off the CVSS vector and the weakness class. Starting points, not rules we have tested.

  • Search application, proxy, and WAF logs for requests touching /Script, /domain.

References

4 on the record

Elsewhere on this site

Not in any source we poll

Listed rather than left blank: an empty field and an unmeasured one look identical on screen, and only one is a reason to look elsewhere.

  • No confirmed IOCs, IP addresses, domains, file hashes, or malware artifacts supplied.
  • No organization-specific asset inventory, compensating-control status, or patch deployment evidence supplied.
  • No exploit packet captures, log samples, or incident case IDs supplied.