CVE Intelligence
Skip to main content
highFile Uploadpublic exploit

CVE-2026-82793

CVE-2026-82793 — Unrestricted upload of file with dangerous type issue exists in Contec CAN 2.0B Communication Wireless LAN / USB Converter Unit

Unrestricted upload of file with dangerous type issue exists in Contec CAN 2.0B Communication Wireless LAN / USB Converter Unit. If a specially crafted file is uploaded by a remote authenticated attacker, arbitrary code may be executed on the product.

Published Updated Sources: NVD, Contec Co., Ltd. (CNA), GitHub, SOCRadar CTI

Triage

Is it exploited, how likely is exploitation, what does it touch, and how severe do the scoring sources call it.

Exploitation

Exploit code

public exploit, none observed

EPSS

0%

ahead of 0% of scored CVEs

Affects

Contec Co., Ltd.

2 products listed

CVSS base

7.2

high · 2 sources

Remediation

The vendor's own words where we have them.

Upgrade CAN-2-WF to a fixed release. Apply vendor patches per advisory and restrict external exposure of the affected component until patched.

First 24 hours

Ordered from the record's own fields — exposure first, because you cannot patch what you have not found.

  • Identify exposed assets running affected vendor/product/version combinations.
  • Prioritize based on EPSS, PoC availability, and external exposure.
  • Search available logs for exploit probes, errors, authentication anomalies, or suspicious child processes matching the vulnerability class.

Affected scope

Vendor, product and version as the advisories word them.

VendorProductVersionsStatus
Contec Co., Ltd.CAN-2-WF0 to < 2.20Vulnerable
Contec Co., Ltd.CAN-2-USB0 to < 2.20Vulnerable

Attack characteristics

The CVSS vector, decoded. It describes the attack, not your exposure to it.

Availability

High

Confidentiality

High

Integrity

High

Scope

Unchanged

Attack Complexity

Low

Attack Vector

Network

Privileges Req

High

User Interaction

None

Every base score collected

Sources score independently and disagree; each row says who scored it and under which version.

ScoreVersionSeverityExpl.ImpactSource
7.2CVSS 3.1high1.25.9jpcert.or.jp (CNA), Contec Co., Ltd. (CNA)
8.6CVSS 4.0high——Contec Co., Ltd. (CNA)

CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H

What this weakness leads to

MITRE's own consequences and mitigations for the weakness class — the authority's wording, not guidance derived from the CVSS vector.

MITRE

CWE-434 · Unrestricted Upload of File with Dangerous Type

  • Execute Unauthorized Code or Commands

Mitigation: Generate a new, unique filename for an uploaded file instead of using the user-supplied filename, so that no external input is used at all.[REF-422] [REF-423]

Weakness & attack patterns

  • CWE-434Unrestricted Upload of File with Dangerous Type

Attack patterns reported against this CVE. The ATT&CK techniques below are inferred from its weakness class.

CAPEC-1 · Accessing Functionality Not Properly Constrained by ACLs
  • T1574.010Hijack Execution Flow: ServicesFile Permissions Weakness

Public exploit

Capability, not use: code existing is a different claim from anyone running it.

Repositories

1

Detection

Read off the CVSS vector and the weakness class. Starting points, not rules we have tested.

  • Prioritize edge telemetry for network-reachable CAN-2-WF, CAN-2-USB.
  • Monitor for scanner or exploit-pattern traffic after 1 public PoC repositories were reported.
web/proxy/WAF logsapplication logsnetwork IDS/IPS

Timeline

What happened to this CVE, newest first — with the readings a source repeats on a schedule counted underneath rather than listed.

  1. 2026
  2. Added · CVSS 3.1 7.2 (AV:N)

    Sep 14, 2026 · NVD

  3. Initial · CVE published

    Sep 14, 2026 · NVD

  4. CVE published by MITRE.

    Sep 14, 2026 · SOCRadar CTI

Source activity

Readings a source repeats on a schedule, counted rather than listed.

  • 1×2 times mentioned on 1 Telegram channelsSep 14, 2026 · SOCRadar CTI

References

2 on the record

Elsewhere on this site

Not in any source we poll

Listed rather than left blank: an empty field and an unmeasured one look identical on screen, and only one is a reason to look elsewhere.

  • No confirmed IOCs, IP addresses, domains, file hashes, or malware artifacts supplied.
  • No organization-specific asset inventory, compensating-control status, or patch deployment evidence supplied.
  • No exploit packet captures, log samples, or incident case IDs supplied.
Answered from this record1

What should defenders know first?

CVE-2026-82793 is Unrestricted upload of file with dangerous type issue exists in Contec CAN 2.0B Communication Wireless LAN / USB Converter Unit, a high vulnerability affecting CAN-2-WF, CAN-2-USB from Contec Co., Ltd.. The current evidence does not list it in CISA KEV, and the exploit status is: Active exploitation is not confirmed from current sources for CVE-2026-82793. Public exploit evidence is: 1 public PoC repositories reported; 0 marked weaponized in current dataset. The affected-version evidence is listed in the key facts and affected products tables. Defenders should first verify whether exposed or business-critical assets run those versions, then apply vendor patches or mitigations, restrict reachable attack surface, and preserve logs for detection review. CVSS 7.2 describes technical severity, while EPSS 0% helps estimate near-term exploit likelihood; neither replaces asset context. Unknown fields should remain explicit in tickets, and threat actor, IOC, victimology, or payload claims should not be added unless a cited source supports them. Monitor CISA KEV, vendor advisories, NVD changes, public PoC repositories, and internal telemetry for update triggers.