CVE-2026-94544
CVE-2026-94544 — Next.js: Pending `use cache` fill can leak Draft Mode content into regular responses and persisted pages
Next.js is a React framework for building full-stack web applications. From 16.3.0 until 16.3.8, pending use cache fills for the same key are shared without separating Draft Mode requests from regular requests. An overlapping regular request can receive unauthenticated unpublished content from an editor's Draft Mode fill, while an overlapping Draft Mode request can receive published content from a regular fill. When the regular request prerenders a page, the draft-dependent content can persist in the generated page and be served to later visitors until revalidation. Sites are affected when Cache Components or experimental.useCache is enabled and cached functions return draft-dependent content. This issue is fixed in version 16.3.8.
Published Updated Sources: NVD, vercel (CNA), GitHub, SOCRadar CTI
Triage
Is it exploited, how likely is exploitation, what does it touch, and how severe do the scoring sources call it.
Exploitation
Exploit code
public exploit, none observed
EPSS
0%
ahead of 0% of scored CVEs
CVSS base
6.3
medium
Remediation
The vendor's own words where we have them.
Upgrade next.js to a fixed release. Apply vendor patches per advisory and restrict external exposure of the affected component until patched.
First 24 hours
Ordered from the record's own fields — exposure first, because you cannot patch what you have not found.
- Identify exposed assets running affected vendor/product/version combinations.
- Prioritize based on EPSS, PoC availability, and external exposure.
- Search available logs for exploit probes, errors, authentication anomalies, or suspicious child processes matching the vulnerability class.
Affected scope
Vendor, product and version as the advisories word them.
| Vendor | Product | Versions | Status |
|---|---|---|---|
| vercel | next.js | >= 16.3.0, < 16.3.8 | Vulnerable |
Attack characteristics
The CVSS vector, decoded. It describes the attack, not your exposure to it.
Scope
X
Attack Complexity
High
Attack Vector
Network
Privileges Req
None
User Interaction
None
Every base score collected
Sources score independently and disagree; each row says who scored it and under which version.
| Score | Version | Severity | Expl. | Impact | Source |
|---|---|---|---|---|---|
| 6.3 | CVSS 4.0 | medium | — | — | vercel (CNA) |
CVSS:4.0/AV:N/AC:H/AT:P/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N
What this weakness leads to
MITRE's own consequences and mitigations for the weakness class — the authority's wording, not guidance derived from the CVSS vector.
CWE-524 · Use of Cache Containing Sensitive Information
- Read Application Data::
Mitigation: Protect information stored in cache.
Weakness & attack patterns
- CWE-524
Attack patterns reported against this CVE. The ATT&CK techniques below are inferred from its weakness class.
- T1005Data from Local System
Public exploit
Capability, not use: code existing is a different claim from anyone running it.
Repositories
1
Detection
Read off the CVSS vector and the weakness class. Starting points, not rules we have tested.
- Prioritize edge telemetry for network-reachable next.js.
- Monitor for scanner or exploit-pattern traffic after 1 public PoC repositories were reported.
Timeline
What happened to this CVE, newest first — with the readings a source repeats on a schedule counted underneath rather than listed.
- 2026
Added · CVSS 3.1 6.3 (AV:N)
Oct 2, 2026 · NVD
Initial · CVE published
Oct 2, 2026 · NVD
CVE published by MITRE.
Oct 2, 2026 · SOCRadar CTI
References
3 on the record
- github.com/vercel/next.js/commit/bd9214f9a32854a011bf5fe58e481dffe1bbf598
Exploit, Third Party Advisory, Mitre, NIST
- github.com/vercel/next.js/releases/tag/v16.3.8
Exploit, Third Party Advisory, Mitre, NIST
- github.com/vercel/next.js/security/advisories/GHSA-3w37-wq28-93x7
Exploit, Third Party Advisory, Mitre, NIST
Elsewhere on this site
- vercelevery CVE for this vendor
- Unclassifiedsame class
- CWE-524other pages naming this weakness
Not in any source we poll
Listed rather than left blank: an empty field and an unmeasured one look identical on screen, and only one is a reason to look elsewhere.
- No confirmed IOCs, IP addresses, domains, file hashes, or malware artifacts supplied.
- No organization-specific asset inventory, compensating-control status, or patch deployment evidence supplied.
- No exploit packet captures, log samples, or incident case IDs supplied.
Answered from this record1
What should defenders know first?
CVE-2026-94544 is Next.js: Pending `use cache` fill can leak Draft Mode content into regular responses and persisted pages, a medium vulnerability affecting next.js from vercel. The current evidence does not list it in CISA KEV, and the exploit status is: Active exploitation is not confirmed from current sources for CVE-2026-94544. Public exploit evidence is: 1 public PoC repositories reported; 0 marked weaponized in current dataset. The affected-version evidence is listed in the key facts and affected products tables. Defenders should first verify whether exposed or business-critical assets run those versions, then apply vendor patches or mitigations, restrict reachable attack surface, and preserve logs for detection review. CVSS 6.3 describes technical severity, while EPSS 0% helps estimate near-term exploit likelihood; neither replaces asset context. Unknown fields should remain explicit in tickets, and threat actor, IOC, victimology, or payload claims should not be added unless a cited source supports them. Monitor CISA KEV, vendor advisories, NVD changes, public PoC repositories, and internal telemetry for update triggers.