CVE-2017-6740
CVE-2017-6740 — Cisco IOS and IOS XE Software SNMP Remote Code Execution Vulnerability
The Simple Network Management Protocol (SNMP) subsystem of Cisco IOS and IOS XE Software contains multiple vulnerabilities that could allow an authenticated, remote attacker to remotely execute code on an affected system or cause an affected system to reload. An attacker could exploit these vulnerabilities by sending a crafted SNMP packet to an affected system via IPv4 or IPv6. Only traffic directed to an affected system can be used to exploit these vulnerabilities. The vulnerabilities are due to a buffer overflow condition in the SNMP subsystem of the affected software. The vulnerabilities affect all versions of SNMP - Versions 1, 2c, and 3. To exploit these vulnerabilities via SNMP Version 2c or earlier, the attacker must know the SNMP read-only community string for the affected system. To exploit these vulnerabilities via SNMP Version 3, the attacker must have user credentials for the affected system. A successful exploit could allow the attacker to execute arbitrary code and obtain full control of the affected system or cause the affected system to reload. Customers are advised to apply the workaround as contained in the Workarounds section below. Fixed software information is available via the Cisco IOS Software Checker. All devices that have enabled SNMP and have not explicitly excluded the affected MIBs or OIDs should be considered vulnerable. There are workarounds that address these vulnerabilities.
Published Updated Sources: NVD, CISA, FIRST EPSS
Triage
Is it exploited, how likely is exploitation, what does it touch, and how severe do the scoring sources call it.
Exploitation
Confirmed
CISA KEV, listed Mar 3, 2022
EPSS
11%
ahead of 96% of scored CVEs
CVSS base
8.8
high · 3 sources
CISA SSVC assessment
Three decision points CISA publishes for the CVEs it assesses · SSVC 2.0.3. A stakeholder decision, not a severity score.
Exploitation
Active
none · proof-of-concept · active
Automatable
No
can an attacker script all four kill-chain steps
Technical impact
Total
partial · total control of the vulnerable component
Remediation
The vendor's own words where we have them.
Upgrade IOS and IOS XE Software to a fixed release. Apply vendor patches per advisory and restrict external exposure of the affected component until patched.
CISA required action
Apply updates per vendor instructions.
Federal deadline Mar 24, 2022 — passed 1,634 days ago
First 24 hours
Ordered from the record's own fields — exposure first, because you cannot patch what you have not found.
- Identify exposed assets running affected vendor/product/version combinations.
- Treat as emergency remediation because CISA KEV status is present.
- Search available logs for exploit probes, errors, authentication anomalies, or suspicious child processes matching the vulnerability class.
Affected scope
Vendor, product and version as the advisories word them.
| Vendor | Product | Versions | Status |
|---|---|---|---|
| Cisco | IOS and IOS XE Software | — | Vulnerable |
Attack characteristics
The CVSS vector, decoded. It describes the attack, not your exposure to it.
Availability
High
Confidentiality
High
Integrity
High
Scope
Unchanged
Attack Complexity
Low
Attack Vector
Network
Privileges Req
Low
User Interaction
None
Every base score collected
Sources score independently and disagree; each row says who scored it and under which version.
| Score | Version | Severity | Expl. | Impact | Source |
|---|---|---|---|---|---|
| 8.8 | CVSS 3.1 | high | 2.8 | 5.9 | NVD |
| 8.8 | CVSS 3.0 | high | 2.8 | 5.9 | Cisco (CNA) |
| 9 | CVSS 2.0 | high | 8 | 10 | NVD |
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Weakness & attack patterns
- CWE-119Improper Restriction of Operations within a Memory Buffer
Inferred from the weakness class — not observed against this CVE.
CISA KEV details
CISA lists a CVE here once it has evidence of exploitation against real targets.
Listed
Mar 3, 2022
Federal deadline
Mar 24, 2022
passed 1,634 days ago
Ransomware use
Unknown
CISA records ransomware use only for campaigns it has confirmed, so “Unknown” means unrecorded, not ruled out. The deadline binds US federal agencies; for everyone else it is a date to argue against.
Detection
Read off the CVSS vector and the weakness class. Starting points, not rules we have tested.
- Prioritize edge telemetry for network-reachable IOS and IOS XE Software.
Timeline
What happened to this CVE, newest first — with the readings a source repeats on a schedule counted underneath rather than listed.
- 2026
Added · CVSS 3.1 8.8 (AV:N)
Jun 17, 2026 · NVD
- 2022
Added to CISA KEV catalog
Mar 3, 2022 · CISA
- 2017
Initial · CVE published
Jul 17, 2017 · NVD
References
6 on the record
- sec.cloudapps.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20170629-snmp
US Government Resource
- www.securityfocus.com/bid/99345
Broken Link, Third Party Advisory, VDB Entry
- www.securitytracker.com/id/1038808
Broken Link, Third Party Advisory, VDB Entry
- tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20170629-snmp
Vendor Advisory
- www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2017-6740
US Government Resource
- nvd.nist.gov/vuln/detail/CVE-2017-6740
Vendor Advisory
Elsewhere on this site
- Ciscoevery CVE for this vendor
- March 2022what else CISA listed
- Memory Corruptionsame class
- CWE-119other pages naming this weakness
Not in any source we poll
Listed rather than left blank: an empty field and an unmeasured one look identical on screen, and only one is a reason to look elsewhere.
- No confirmed IOCs, IP addresses, domains, file hashes, or malware artifacts supplied.
- No organization-specific asset inventory, compensating-control status, or patch deployment evidence supplied.
- No exploit packet captures, log samples, or incident case IDs supplied.
Answered from this record1
What should defenders know first?
CVE-2017-6740 is Cisco IOS and IOS XE Software SNMP Remote Code Execution Vulnerability, a high vulnerability affecting IOS and IOS XE Software from Cisco. The current evidence lists it in CISA KEV, and the exploit status is: Yes: CISA KEV signal present. Public exploit evidence is: A public PoC is not confirmed from current sources for CVE-2017-6740. The affected-version evidence is listed in the key facts and affected products tables. Defenders should first verify whether exposed or business-critical assets run those versions, then apply vendor patches or mitigations, restrict reachable attack surface, and preserve logs for detection review. CVSS 8.8 describes technical severity, while EPSS 11% helps estimate near-term exploit likelihood; neither replaces asset context. Unknown fields should remain explicit in tickets, and threat actor, IOC, victimology, or payload claims should not be added unless a cited source supports them. Monitor CISA KEV, vendor advisories, NVD changes, public PoC repositories, and internal telemetry for update triggers.